Welcome to QET, where innovation meets precision in laboratory equipments! As a leading provider in the field, we take pride in offering cutting edge solutions to meet the diverse the needs of modern laboratories. Our commitment to excellence, reliability, and customer satisfaction sets us apart in the world of laboratory equipment trading.

FLAKINESS SIEVE SET

  • Used to determine if the aggregate particles are classified as flaky or not, when they have a thickness (smallest dimension) of less than 0.6 of their mean sieve size, this size being taken as the mean of the limiting sieve apertures used for determining the size fraction in which the particle occurs.
  • The flakiness index of an aggregate sample is found by separating the flaky particles and expressing their mass as a percentage of the mass of the sample tested.
  • The test cannot be used for material that either passes through a 6.30 mm test sieve or is held back by a 63.0 mm test sieve.